Discover high-quality accessories designed to support reliable motor control and hydraulic testing applications. Our range includes auto transporter starters, DOL control panels, hydraulic test pumps, induction motors, submersible motor control panels, star-delta control panels, and two-phase motor control panels, offering dependable performance, efficient operation, and practical solutions for diverse industrial requirements.
| Metal Box | CRC/FRP/Galvanized Sheet with Powder coated (We can provide design IP55/IP54/IP43/IP65 as per customer requirement) |
| Contactor | Schneider/BCH/Chint/ABB (Reputed) |
| MCB/MCCB | Schneider/BCH/Teknic/C&S/Indo Asian (Reputed) |
| Digital Ammeter | (0-30/50/150/450/800 Amps) R-Y-B: Kaizen |
| Digital Voltmeter | (0-500 Volt) RY-YB-BR: Kaizen |
| Overload Protection | (As per Motor Rating) Variable with 0 to 60 Sec Time |
| Underload Protection | (As per Motor Rating) Variable with 0 to 60 Sec Time |
| Over Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Under Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Single Phase Preventer | With current and Voltage Sensing |
| Switch | Auto-Manual |
| Power and Control wiring | Copper |
| Output | Terminals |
| Indicating Lamp | R-Y-B (22.5 sq mm LED Type) |
| Push Button | On/OFF (22.5 sq mm) |
| Metal Box | CRC Sheet with Powder coated |
| Contactor | Schneider/ BCH/C&S (Reputed) |
| MCB/MCCB | Schneider/Teknic/C&S/Indo Asian (Reputed) |
| Analog Ammeter | OA-30A (as per motor current rating) |
| Analog Voltmeter | OV-240V (Single Phase), OV-500V (Two Phase) |
| Starting Capacitor | As per Customer requirement |
| Running Capacitor | As per Customer requirement |
| Pickup Voltage | 190-240 V |
| Power And Control wiring | Copper |
| Output | Terminals |
| Indicating Lamp | LED Type |
| Push Button | On/OFF |
| Metal Box | CRC Sheet with Powder Coated |
| Contactor | Schneider/ BCH/C&S (Reputed) |
| MCB/MCCB | Schneider/ Teknic/C&S/Indo Asian (Reputed) |
| Analog Ammeter | OA-30A (as per motor current rating) |
| Analog Voltmeter | OV-240V (Single-Phase), OV-500V (Two Phase) |
| Starting Capacitor | As per Customer requirement |
| Running Capacitor | As per Customer requirement |
| Pickup Voltage | 120-240 V(Single-Phase) |
| Power And Control wiring | Copper |
| Output | Terminals |
| Indicating Lamp | LED Type |
| Push Button | On/OFF |
| Metal Box | CRC/FRP/Galvanized Sheet with Powder Coated (We can provide design IP55/IP54/IP43/IP65 as per customer requirement) |
| Contactor | Schneider/BCH/Chmt/ABB (Reputed) |
| MCB/MCCB | Schneider/BCH/Teknic/C&S/Indo Asian (Reputed) |
| Digital Ammeter | (0-30/50/150/450/800 Amps) R-Y-B: Kaizen |
| Digital Voltmeter | (0-500 Volt) RY-YB-BR Kaizen |
| Overload Protection | (As per Motor Rating) Variable with 0 to GO Sec Time |
| Underload Protection | (As per Motor Rating) Variable with 0 to 60 Sec Time |
| Over Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Under Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Single Phase Preventer | With Current and Voltage Sensing |
| Switch | Auto-Manual |
| Power and Control Wiring | Copper |
| Output | Terminals |
| Indicating Lamp | R-Y-B (22.5 sq mm LED Type) |
| Push Button | On/Off (22.5 sq mm) |
| Metal Box | CRC/FRP/Galvanized Sheet with Powder coated. (We can provide design IP55/ IP54/ IP43/ IP6S as per customer requirement) |
| Contactor | Schneider/BCH/Chint/ABB (Reputed) |
| MCB/MCCB | Schneider/BCH/Teknic/C&S/Indo Asian (Reputed) |
| Digital Ammeter | (0-30/50/150/450/800 Amps) R-Y-B: Kaizen |
| Digital Voltmeter | (0 500 Volt) RY-YB-BR: Kaizen |
| Overload Protection | (As per Motor Rating) Variable with 0 to 60 Sec Time |
| Underload Protection | (As per Motor Rating) Variable with 0 to 60 Sec Time |
| Over Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Under Voltage Protection | (300-500 Volt) Variable with 0 to 60 Sec Time |
| Single Phase Preventer | With Current and Voltage Sensing |
| Switch | Auto-Manual |
| Power and Control Wiring | Copper |
| Output | Terminals |
| Indicating Lamp | R-Y-B (22.5 sq mm LED Type) |
| Push Button | On/OFF (22.5 sq mm) |
| Capacity | Up to 150 LPH |
| Discharge Size | ½” BSP |
| Plunger Size | 12 mm to 24 mm |
| Pressure | Up to 700 kg/cm |
| KW/HP | Up to 3.7/5 |
| Pressure | 700 kg/cm³ max. |
| Discharge Size | W” BSP |
| Pail Size | 22 Itr |
| Plunger Size | 12 mm to 24 mm |
| Output CC/Stroke | 5.65 to 15.70 |
| Type | Squirrel Cage Induction Motor IE2, IE3 & IE4 |
| Power Range | 0.5HP to 3.0 HP, 0.5HP to 425HP |
| Frame Size | 63 to 355 L |
| Speed | 2900/1450/960/740 rpm |
| Version | 1ph-CST/CSCR, 3ph-DOL/SD |
| Insulation Class | “B”/”F” Class |
| Protection | IP 44/IP 55 |
| Duty | S1 continuous |
| Mounting | Foot (B3)/Flange (B5)/Face (B14)/Foot-cum-Flange (B35)/Foot-cum-face (B34) |
| Direction of Rotation | Bi-directional |